Pressure transient analysis

Drawdown-buildup test designer

Design a single-rate drawdown and a shut-in, choose a reservoir boundary model, and read the diagnostic plots.

Live

Boundary model

Test design

Flow rateq
STB/d
Drawdown durationtp
h
Shut-in durationΔt
h
Initial pressurepi
psi

Reservoir and well

Permeabilityk
mD
SkinS
Net payh
ft
Porosityφ
frac
Wellbore storageC
bbl/psi
Wellbore radiusrw
ft
Distance to boundary 1L1
ft

Fluid

Oil viscosityμ
cP
Formation volume factorB
bbl/STB
Total compressibilityct
1e-6/psi

Interpretation

Interpreted k 48.4mD-3.3% vs input
Interpreted skin 2.65-0.35 vs input
p* (Horner) 4,992psipi 5,000, difference -8 psi
End of storage 0.71h(200 000 + 12 000 S) C μ / kh
Radius investigated 1,019ftat the end of the drawdown

Log-log diagnostic

Dp (psi)Derivative (psi)Infinite (psi)
T (h)

Horner plot

Ratio

Test history

Time (h)

Interpretation check

5 rows
QuantityInputInterpretedDifferenceMethod
Permeability k, mD50.048.37-3.3%70.6 qBμ / (h Δp′)
Flow capacity kh, mD ft3,0002,902-3.3%radial derivative level
Skin S3.002.65-0.35Horner p at 1 h
Semilog slope m, psi/cycle30.531.5+3.4%2.303 Δp′
Extrapolated p*, psi5,000 (pi)4,992-8 psiboundaries shift p* from pi

Calculation record

  1. Ran – Sealing fault: q 500, tp 48, Δt 72, pi 5000, k 50, S 3, h 60, φ 0.18, C 0.01, rw 0.354, L1 400, L2 900, μ 0.9, B 1.25, ct 12

Notes

Field units. A vertical well in a homogeneous reservoir, with constant wellbore storage and skin and a single-phase, slightly compressible liquid. The buildup derivative is taken against Agarwal's equivalent time tp Δt / (tp + Δt) and plotted against Δt. Boundary-felt times use t ≈ 3 800 φμct L² / k. The radius of investigation is 0.029 √(k t / φμct).