Reservoir

Well

Operating point

Rate 2,171STB/d72 % of the AOF
Flowing bottom-hole pressure 1,434psiabelow the bubble point
Drawdown 1,566psi
AOF 3,033STB/dthe inflow at zero flowing pressure
Unstable crossings 1where the well would load up

Inflow against outflow

Inflow (psia)Outflow (psia)
Rate (STB/d)

Curves

40 rows
RateInflowOutflow
STB/dpsiapsia
75.82949.42010.6
151.72898.91296
227.52848.31044.1
303.32797.81056.8
379.22747.21076.4
4552696.71094.9
530.82646.11112.6
606.72595.61129.5
682.525451145.9
758.32494.41161.9
834.22443.91177.6
9102393.31192.9
985.82342.81208.1
1061.72292.21223
1137.52241.71237.8
1213.32191.11252.5
1289.22139.81267
13652087.41281.5
1440.82033.91295.9
1516.719791310.3
1592.51922.81324.7
1668.31865.11339
1744.21805.81353.3
18201744.81367.6
1895.81681.91381.9
1971.71616.91396.3
2047.51549.51410.6
2123.31479.61425
2199.21406.81439.4
22751330.71453.8
2350.81250.71468.2
2426.71166.41482.7
2502.51076.81497.3
2578.3980.81511.8
2654.2876.91526.4
2730762.61541.1
2805.8634.11555.8
2881.74841570.5
2957.5295.91585.3
3033.301600.2

Notes

Field units. The inflow is generalized Vogel: straight above the bubble point, Vogel's curve below it. The outflow is Hagedorn & Brown in vertical tubing, for a 53 lb/ft³, 1.2 cP liquid and a 0.7 gravity gas at 180 °F. The operating point is the stable crossing of the two: where the outflow curve rises through the inflow curve.