Pump

Well

Operating point

Rate at the pump 1,293bbl/d1026 STB/d in the tank
Of the best efficiency point 90%Acceptable
Intake pressure 2,247psisubmerged
Total dynamic head 4,294ft
Brake horsepower 60hpat the operating point

Pump head against the well's system curve

Pump (ft)Well (ft)
Rate (bbl/d)

Curves

26 rows
RatePumpWell
bbl/dftft
3755660.4102.7
4505607.2437.9
5255546.1774.4
6005473.31112.3
6755385.11451.6
7505281.51792.2
8255165.22134.2
9005039.22477.4
9754906.12821.9
105047683167.6
11254625.53514.6
12004479.33862.8
12754329.94212.3
13504174.94562.9
142540054914.8
15003810.15267.8
157535805622
16503310.15977.4
17253017.86333.9
18002726.36691.7
18752458.77050.5
19502227.17410.5
202519657771.6
21001570.38133.9
2175940.68497.3
2250-08861.8

Notes

Field units, rates at the pump in intake barrels (Bo 1.26). The pump is the 50 Hz catalogue curve of Economides et al. (1994) Fig. 20-11, carried to the drive frequency by the affinity laws: rate with the speed ratio, head with its square. The well's system curve is the head the pump must add: the lift from the intake to the surface, the wellhead pressure and the tubing friction (simplified Hazen-Williams), less the intake pressure the productivity index leaves. A 0.865 gravity liquid on 2.259 in tubing; no free gas at the intake.