| Rate | Pump | Well |
|---|---|---|
| bbl/d | ft | ft |
| 375 | 5660.4 | 102.7 |
| 450 | 5607.2 | 437.9 |
| 525 | 5546.1 | 774.4 |
| 600 | 5473.3 | 1112.3 |
| 675 | 5385.1 | 1451.6 |
| 750 | 5281.5 | 1792.2 |
| 825 | 5165.2 | 2134.2 |
| 900 | 5039.2 | 2477.4 |
| 975 | 4906.1 | 2821.9 |
| 1050 | 4768 | 3167.6 |
| 1125 | 4625.5 | 3514.6 |
| 1200 | 4479.3 | 3862.8 |
| 1275 | 4329.9 | 4212.3 |
| 1350 | 4174.9 | 4562.9 |
| 1425 | 4005 | 4914.8 |
| 1500 | 3810.1 | 5267.8 |
| 1575 | 3580 | 5622 |
| 1650 | 3310.1 | 5977.4 |
| 1725 | 3017.8 | 6333.9 |
| 1800 | 2726.3 | 6691.7 |
| 1875 | 2458.7 | 7050.5 |
| 1950 | 2227.1 | 7410.5 |
| 2025 | 1965 | 7771.6 |
| 2100 | 1570.3 | 8133.9 |
| 2175 | 940.6 | 8497.3 |
| 2250 | -0 | 8861.8 |
Field units, rates at the pump in intake barrels (Bo 1.26). The pump is the 50 Hz catalogue curve of Economides et al. (1994) Fig. 20-11, carried to the drive frequency by the affinity laws: rate with the speed ratio, head with its square. The well's system curve is the head the pump must add: the lift from the intake to the surface, the wellhead pressure and the tubing friction (simplified Hazen-Williams), less the intake pressure the productivity index leaves. A 0.865 gravity liquid on 2.259 in tubing; no free gas at the intake.