Duty

Machine

The train

Shaft power 1,178kW1 × ratio 3.33
Hottest discharge 144.6°Cwithin a 150 °C limit
Cooling duty 1,737kWintercoolers and aftercooler
Liquid knocked out 0kg/hin the scrubbers

One to four stages at these settings

Stages (stages)
Stages (stages)

Stages

1 row
StageRatioIsentropicDischargePowerCooler
stageratio°C°CkWkW
13.333126.4144.611781737

Notes

Each stage is a Team76.Engineering.Process Compressor at one pressure ratio, (Pd/Ps)^(1/n), and one isentropic efficiency: a PS flash for the isentropic outlet, H2 = H1 + (H2s - H1)/eta, then a PH flash for the actual outlet. A Heater cools each discharge to the cooler outlet temperature, and a Separator at the stage pressure scrubs out the liquid before the next stage. The vapour is 20 MMscf/d of an associated gas (78 % methane) at 40 °C, Peng-Robinson with estimated kij. Equal ratios are the textbook minimum-power split for equal suction temperatures; the power is shaft power with no mechanical losses.