| Stage | Ratio | Isentropic | Discharge | Power | Cooler |
|---|---|---|---|---|---|
| stage | ratio | °C | °C | kW | kW |
| 1 | 3.333 | 126.4 | 144.6 | 1178 | 1737 |
Each stage is a Team76.Engineering.Process Compressor at one pressure ratio, (Pd/Ps)^(1/n), and one isentropic efficiency: a PS flash for the isentropic outlet, H2 = H1 + (H2s - H1)/eta, then a PH flash for the actual outlet. A Heater cools each discharge to the cooler outlet temperature, and a Separator at the stage pressure scrubs out the liquid before the next stage. The vapour is 20 MMscf/d of an associated gas (78 % methane) at 40 °C, Peng-Robinson with estimated kij. Equal ratios are the textbook minimum-power split for equal suction temperatures; the power is shaft power with no mechanical losses.