Set a lift valve's dome charge for the test rack
An injection-pressure-operated lift valve, from the casing pressure it has to open at downhole to the nitrogen charge and test rack opening pressure the shop sets it to at 60 °F: the dome pressure at depth, the closing pressure, the spread, and how the opening pressure moves with the tubing pressure.
- UC-GL-001
- UC-GL-002
Engineering use cases UC-GL-001 (Calculate Valve Opening Pressure) and UC-GL-002 (Determine Test Rack Setting), on Guo et al. (2007) Example 13.7.
The valve is a nitrogen-charged bellows held on its seat by the dome pressure Pd. Casing pressure acts on the bellows area, tubing pressure on the port, so it opens when Pc (1 − R) + Pt R ≥ Pd, that is Pvo = (Pd − R Pt) / (1 − R). Once it is open the casing pressure acts on the whole bellows and it closes at Pvc = Pd. The charge is set on the rack at 60 °F and grows with the downhole temperature at constant volume (p / zT constant, with the nitrogen z factor).
What an engineer learns from it: to open at 953 psia against 424 psia in the tubing, the top valve needs 817 psia in its dome at 126 °F, and closes at 817 psia: a 136 psi spread, R / (1 − R) × (Pd − Pt). The shop charges it to 717 psia at 60 °F, and it opens on the rack at 958 psia with an atmosphere on the port. The table shows why the design tubing pressure matters: every 100 psi more in the tubing takes R / (1 − R) × 100 ≈ 34 psi off the casing pressure the valve opens at, the production pressure effect, so a valve designed for the wrong tubing pressure opens out of sequence.
Units are field: psia and °F. The book prints 683 and 918 psia for the charge and the rack pressure, because it takes the lift gas's z factors (0.80 and 0.85) for the dome; this uses nitrogen's. No spring.
Source
using System;
using System.Linq;
using Team76.Engineering.AL.GL;
public class S : ICalcScript
{
public ScriptResult Run(ICalcContext ctx)
{
// Guo et al. (2007) Example 13.7, the top valve: an IPO unbalanced-bellows valve at 2,347 ft and 126 °F, port to
// bellows area ratio R = 0.2562, designed against 424 psia in the tubing and to open at 953 psia in the casing.
const double r = 0.2562, valveTemperature = 126, tubingPressure = 424, openingPressure = 953;
// Downhole: the dome pressure that opens it at 953 psia, and the pressure that closes it again.
double domeAtDepth = Valve.RequiredDomePressure(openingPressure, r, tubingPressure);
double closing = Valve.ClosingPressure(domeAtDepth, r);
double spread = Valve.Spread(openingPressure, closing);
// On the shop's test rack: the nitrogen charge at 60 °F, and the pressure the valve opens at there.
double domeCharge = Valve.DomePressureAtSurface(domeAtDepth, Valve.TestRackTemperature, valveTemperature);
double rackOpening = Valve.TestRackOpeningPressure(domeAtDepth, valveTemperature, r);
// The tubing pressure helps open the valve: the casing pressure it needs falls as the tubing pressure rises.
var rows = Enumerable.Range(0, 9)
.Select(i => i * 100.0)
.Select(pt => new object[]
{
pt,
Math.Round(Valve.OpeningPressure(domeAtDepth, r, pt)),
Math.Round(Valve.Spread(Valve.OpeningPressure(domeAtDepth, r, pt), closing)),
})
.ToList();
return ctx.Result()
.Set("Dome pressure at depth (psia)", Math.Round(domeAtDepth))
.Set("Closing pressure at depth (psia)", Math.Round(closing))
.Set("Spread (psi)", Math.Round(spread))
.Set("Production pressure effect factor", Math.Round(Valve.ProductionPressureEffectFactor(r), 3))
.Set("Dome charge at 60 °F (psia)", Math.Round(domeCharge))
.Set("Test rack opening pressure (psia)", Math.Round(rackOpening))
.Set("Table", new ScriptTable(["Tubing pressure (psia)", "Opening pressure (psia)", "Spread (psi)"], rows,
title: "Opening pressure against tubing pressure, same dome charge"));
}
}