Size a steamflood's heated zone and its oil-steam ratio

1,000 bbl/d of 80 % quality steam at 500 psia into 30 ft of heavy-oil sand: the steam's temperature and the heat it carries, the Marx–Langenheim heated area and the share of the heat still in the sand year by year, and the Myhill–Stegemeier oil-steam ratio.

Open in the workbench

Engineering use cases UC-STEAM-001 (Saturated steam T(P) and enthalpy), UC-STEAM-002 (Marx–Langenheim heated area vs time) and UC-STEAM-005 (Myhill–Stegemeier oil–steam ratio).

The heat injected above the reservoir is Hi = w (hf − hr + x hfg), with the steam's enthalpies from the IAPWS saturation line. Marx and Langenheim (1959) grow the steam zone against conduction into the cap and base rock: As = Hi h G(tD) / (4 K ΔT), with tD = 4 (K/M) t / h² and G(tD) = e^tD erfc √tD + 2 √(tD/π) − 1. Myhill and Stegemeier (1978) turn the heat left in the zone into oil: OSR = Eh Hi φ ΔSo / (is M ΔT × 5.615 Bo), with the latent-heat fraction fhv taking over after the Mandl–Volek critical time.

What an engineer learns from it: 500 psia steam is at 467 °F, 367 °F above the sand. 1,000 bbl/d at 80 % quality carries 346 MMBtu/d, 61 % of it as latent heat. After a year (tD 1.78) the zone covers 3.6 acres (346 × 10⁶ × 30 × G / (4 × 38.4 × 367) ft²) and only 48 % of the heat injected is still in the sand; after ten years the zone is 16.4 acres and 22 % is left. The cumulative oil-steam ratio falls from 0.26 after the first year to 0.085 after ten: thin sands lose their heat to the cap and base rock, which is why a steamflood wants thick pay and why OSR, not the heated area, sets the economics.

Units: psia, °F, Btu/d, Btu/(ft d °F) (1.6 Btu/(ft h °F) × 24), Btu/(ft³ °F), ft, acres, bbl/bbl (stock-tank oil per bbl cold water equivalent). The library's steam enthalpies cover 90 to 300 °C, so the 100 °F reservoir water is taken at 1 Btu/(lb °F) above 32 °F. Marx–Langenheim assumes the cap and base rock have the sand's heat capacity and no steam override; see van Lookeren for the override.

Source

using System;
using System.Linq;
using Team76.Engineering.Core.Measures;
using Team76.Engineering.EoR.Steam;

public class S : ICalcScript
{
    public ScriptResult Run(ICalcContext ctx)
    {
        // 1,000 bbl/d (cold water equivalent) of 80 % quality steam at 500 psia into 30 ft of heavy-oil sand at 100 °F.
        // Overburden conductivity 1.6 Btu/(ft h °F), reservoir heat capacity 35 Btu/(ft3 °F); porosity 0.30, So 0.75 to 0.30.
        double cwe = 1000, quality = 0.80, k = 1.6 * 24, m = 35;
        var pay = Length.FromFeet(30);
        var reservoir = Temperature.FromDegF(100);
        const double BtuPerLbPerKjPerKg = 0.429923, LbPerBbl = 350.5;

        // The steam: saturation temperature and enthalpies at the injection pressure.
        var steamT = SaturatedSteam.Temperature(Pressure.FromPsi(500));
        double hf = SaturatedSteam.LiquidEnthalpyKjPerKg(steamT) * BtuPerLbPerKjPerKg;
        double hfg = SaturatedSteam.LatentHeatKjPerKg(steamT) * BtuPerLbPerKjPerKg;
        // The steam tables start at 90 °C; below it, water's enthalpy over 32 °F is its 1 Btu/(lb °F) times the rise.
        double hr = 1.0 * (reservoir.DegF - 32);

        // Heat injected above the reservoir, and the share of it carried as latent heat.
        double heat = cwe * LbPerBbl * (hf - hr + quality * hfg);
        double latent = quality * hfg / (hf - hr + quality * hfg);
        double dT = steamT.DegF - reservoir.DegF;

        // Marx-Langenheim: the steam zone grows while the cap and base rock take an ever larger share of the heat.
        double Area(double days) => MarxLangenheim.HeatedArea(heat, k, m, pay, dT, days).Ft2 / 43560;
        OilSteamRatioReport Osr(double days) => MyhillStegemeier.Evaluate(
            MarxLangenheim.DimensionlessTime(days, k, m, pay), latent, heat, cwe, m, dT, porosity: 0.30, oilSaturationChange: 0.45, oilFvfRbPerStb: 1.05);

        var years = Enumerable.Range(1, 40).Select(i => i * 0.25).ToArray();
        var chart = new ScriptChart(
            [
                new ScriptSeries("Heated area (acres)", years, years.Select(y => Area(y * 365)).ToArray()),
                new ScriptSeries("Heat still in the sand (%)", years, years.Select(y => 100 * MarxLangenheim.CumulativeHeatRemainingFraction(MarxLangenheim.DimensionlessTime(y * 365, k, m, pay))).ToArray()),
            ],
            title: "Marx-Langenheim steam zone", xLabel: "Years of injection", yLabel: "Acres, or %");

        var rows = new[] { 1.0, 2, 3, 5, 10 }
            .Select(y =>
            {
                var r = Osr(y * 365);
                return new object[]
                {
                    y, Math.Round(r.DimensionlessTime, 2), Math.Round(Area(y * 365), 1), Math.Round(100 * MarxLangenheim.CumulativeHeatRemainingFraction(r.DimensionlessTime), 1),
                    Math.Round(r.CumulativeOilSteamRatio, 3), Math.Round(r.InstantaneousOilSteamRatio, 3),
                };
            })
            .ToList();
        var first = Osr(365);

        return ctx.Result()
            .Set("Steam zone", chart)
            .Set("By year", new ScriptTable(["Year", "tD", "Heated area (acres)", "Heat in the sand (%)", "Cumulative OSR", "Instantaneous OSR"], rows))
            .Set("Steam temperature (°F)", Math.Round(steamT.DegF, 1))
            .Set("Heat injection (MMBtu/d)", Math.Round(heat / 1e6, 1))
            .Set("Latent heat fraction", Math.Round(latent, 3))
            .Set("Heated area after 1 year (acres)", Math.Round(Area(365), 1))
            .Set("Critical time tDc", Math.Round(first.DimensionlessCriticalTime, 3))
            .Set("Cumulative OSR after 1 year", Math.Round(first.CumulativeOilSteamRatio, 3));
    }
}