Lower the residual oil with a surfactant slug
The capillary number of a waterflood and of a Winsor III microemulsion slug, the slug's interfacial tension from its solubilization ratio by Huh, and the residual oil each leaves on the capillary desaturation curve.
- UC-CHEM-001
- UC-CHEM-002
- UC-CHEM-003
Engineering use cases UC-CHEM-001 (Estimate Huh IFT vs solubilization ratio), UC-CHEM-002 (Compute Taber capillary number) and UC-CHEM-003 (Read Sor from the class CDC).
The capillary number is Taber's Nc = μ v / σ, viscous over capillary forces. Huh (1979) relates a microemulsion's interfacial tension to its solubilization ratio, σ = C / N², with C = 0.3 dyne/cm as UTCHEM and Sheng (2011) restate it. The capillary desaturation curve is the Stegemeier and Lake class curve: residual oil stays at its waterflood value up to Nc = 10⁻⁵ and falls log-linearly to the miscible value at 10⁻².
What an engineer learns from it: brine of 0.5 cP at 1 ft/d against a 30 dyne/cm oil gives Nc = 5.9 × 10⁻⁸, two decades below the onset, so the waterflood leaves its full Sorw of 0.30, however fast it is pushed. A surfactant slug that solubilises 10 volumes of oil per volume of surfactant drops the tension to 0.3 / 10² = 0.003 dyne/cm, ten thousand times lower, and Nc to 5.9 × 10⁻⁴; the residual falls to 0.30 × (1 − log10(59) / 3) = 0.123, so 0.18 of the pore volume becomes mobile. Velocity cannot do this: the capillary number has to rise by four decades, and only the tension can move that far.
Units: cP, ft/d (converted to m/s), dyne/cm; Nc is dimensionless when μ is in cP, v in m/s and σ in dyne/cm, the Core storage units. The class curve is for water-wet sandstone; fit it to a coreflood before design, and the slug has to keep its low tension against adsorption and dilution, which this entry does not model.
Source
using System;
using System.Linq;
using Team76.Engineering.Core.Measures;
using Team76.Engineering.EoR.Chemical;
public class S : ICalcScript
{
public ScriptResult Run(ICalcContext ctx)
{
// Brine of 0.5 cP moving at 1 ft/d through a water-wet sandstone that a waterflood leaves at Sorw 0.30.
var brine = Viscosity.FromCP(0.5);
var velocity = Velocity.FromFtPerS(1.0 / 86400);
double sorw = 0.30;
// The waterflood: oil-brine IFT 30 dyne/cm.
double ncWater = CapillaryNumber.FromDarcy(brine, velocity, InterfacialTension.FromDynesPerCm(30));
// A Winsor III microemulsion with a solubilization ratio of 10: Huh's sigma = C / N^2.
var ift = MicroemulsionIft.ByHuh1979(solubilizationRatio: 10);
double ncSlug = CapillaryNumber.FromDarcy(brine, velocity, ift);
// The capillary desaturation curve: Sor falls log-linearly from Nc 1e-5 to 1e-2.
double sorWater = ResidualOilSaturation.ByStegemeier(ncWater, sorw);
double sorSlug = ResidualOilSaturation.ByStegemeier(ncSlug, sorw);
var exponents = Enumerable.Range(0, 37).Select(i => -8 + i * 0.2).ToArray();
var nc = exponents.Select(e => Math.Pow(10, e)).ToArray();
var cdc = new ScriptChart(
[new ScriptSeries("Sor", nc, nc.Select(n => ResidualOilSaturation.ByStegemeier(n, sorw)).ToArray())],
title: "Capillary desaturation curve", xLabel: "Capillary number", yLabel: "Residual oil (fraction)", xLog: true);
var rows = new[] { 2.0, 5, 10, 15, 20 }
.Select(n =>
{
var sigma = MicroemulsionIft.ByHuh1979(n);
var c = CapillaryNumber.FromDarcy(brine, velocity, sigma);
return new object[] { n, Math.Round(sigma.DynesPerCm, 5), c.ToString("0.0E+0", System.Globalization.CultureInfo.InvariantCulture), Math.Round(ResidualOilSaturation.ByStegemeier(c, sorw), 3) };
})
.ToList();
return ctx.Result()
.Set("Capillary desaturation", cdc)
.Set("By solubilization ratio", new ScriptTable(["Solubilization ratio", "IFT (dyne/cm)", "Capillary number", "Sor"], rows))
.Set("Waterflood capillary number", ncWater.ToString("0.00E+0", System.Globalization.CultureInfo.InvariantCulture))
.Set("Microemulsion IFT (dyne/cm)", Math.Round(ift.DynesPerCm, 4))
.Set("Slug capillary number", ncSlug.ToString("0.00E+0", System.Globalization.CultureInfo.InvariantCulture))
.Set("Sor after the waterflood", Math.Round(sorWater, 3))
.Set("Sor after the slug", Math.Round(sorSlug, 3))
.Set("Oil mobilised (fraction of pore volume)", Math.Round(sorWater - sorSlug, 3));
}
}